Bulb Turbine / Bulb Tubular Turbine / Hydro Turbine / Water Turbine
Tubular Turbine
The tubular turbines are the best selection for exploitation of tidal power and hydraulic power with extremely low heads and extremely large flow rates. They have large discharge, high specific and high efficiency, and need less excavation.
They have been classified into Bulb, Pit, Siphon and "S" types in the light of their structural types.
The tubular turbine requires less space than other turbines, a saving in civil costs is realized due to a smaller powerhouse and shallow requirements for the draft tube, which is equipped with adjustable wicket gates and adjustable runner blades. This arrangement provides the greatest possible flexibility in adapting to changing net head and changing demands for power output; because the gates and blades can be adjusted to their optimum openings.
At present, Fuchun has developed 16 varieties of tubular turbines, ranging from 2 to 25m in water head, 200KW to 16MW in capacity, and 0.8m to 5.8m in runner diameter. They offered the best selection for exploitation of low head hydropower resources.
Company
Our company is an experienced manufacture and engineering Company in small scale hydro power equipment ( 100Kw to 50Mw). We play the role of manufacture and EPC contractor and could supply water to wire equipments and services. As turbine manufacture more than 50 years experience.
Our factory occupies 560,000 square meters of land, which includes 18 workshops, over 320 sets of heavy and precision producing and testing machinery; scientific research development center in the southern China, and various testing facilities. We have a general technical staff of 380 and 135 senior technical professionals.
We provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.
1.Water Turbine Generator Unit Design & SUPPLY
2.Hydropower equipment supply
3.Feasibility study of hydropower project
4.Manufacture
5.Installation & Supervision
6.Commissioning and Training service
7. Hydro power plant rehabilitant
8. Hydro power plant spares supply
9.Services
Tubular Turbine
The tubular turbines are the best selection for exploitation of tidal power and hydraulic power with extremely low heads and extremely large flow rates. They have large discharge, high specific and high efficiency, and need less excavation.
They have been classified into Bulb, Pit, Siphon and "S" types in the light of their structural types.
The tubular turbine requires less space than other turbines, a saving in civil costs is realized due to a smaller powerhouse and shallow requirements for the draft tube, which is equipped with adjustable wicket gates and adjustable runner blades. This arrangement provides the greatest possible flexibility in adapting to changing net head and changing demands for power output; because the gates and blades can be adjusted to their optimum openings.
At present, Fuchun has developed 16 varieties of tubular turbines, ranging from 2 to 25m in water head, 200KW to 16MW in capacity, and 0.8m to 5.8m in runner diameter. They offered the best selection for exploitation of low head hydropower resources.
Company
Our company is an experienced manufacture and engineering Company in small scale hydro power equipment ( 100Kw to 50Mw). We play the role of manufacture and EPC contractor and could supply water to wire equipments and services. As turbine manufacture more than 50 years experience.
Our factory occupies 560,000 square meters of land, which includes 18 workshops, over 320 sets of heavy and precision producing and testing machinery; scientific research development center in the southern China, and various testing facilities. We have a general technical staff of 380 and 135 senior technical professionals.
We provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.
1.Water Turbine Generator Unit Design & SUPPLY
2.Hydropower equipment supply
3.Feasibility study of hydropower project
4.Manufacture
5.Installation & Supervision
6.Commissioning and Training service
7. Hydro power plant rehabilitant
8. Hydro power plant spares supply
9.Services
Reference List of Some Export Projects | |||||
No. | Country and Power Station Exported to | Technical Parameters | Type | Qty | Date of contract |
1 | HPP2 Guatemala | Rated head:305m Rated flow:0.385m³/s Frequency:60Hz Outgoing line voltage:480V | CJA475-W-80/2×6.5 SFW1000-8/1180 | 1 | 2013.06 |
2 | Pakistan | Type:HL855a Runner diameter:1750mm | 27Mw spare runners | 1 | 2013.06 |
3 | UK | Rated head:73.8m Rated flow:0.1325m³/s Frequency:50Hz Outgoing line voltage:400V | CJA237-W-55/1×7 | 1 | 2013.03 |
4 | turkey | Rated head:203m Rated flow:0.312m³/s Frequency:50Hz Outgoing line voltage:400V | CJA237-W-80/1×8.5 SFW500-8/990 | 1 | 2013.05 |
5 | Sri Lanka | Rated head:88m Rated flow:1.41m³/s Frequency:50Hz Outgoing line voltage:400V | HLA550-WJ-62 SFW1000-6/1180 | 1 | 2013.05 |
6 | Congo | Rated head:210m Rated flow:0.423m³/s Frequency:50Hz Outgoing line voltage:400V | CJA237-W-80/1×9.5 SFW700-8/1180 | 1 | 2013.05 |
7 | Ecuador | Rated head:925m Rated flow:0.26m³/s Frequency:60Hz Outgoing line voltage:4.16KV | CJC601-W-100/1×5 SFW1980-6/1430 | 2 | 2012.12 |
8 | Philippines | Rated head:4m Rated flow:10m³/s Frequency:60Hz Outgoing line voltage:440V | ZD-LH-160 SF320-36/2150 | 1 | 2012.12 |
9 | Guatemala | Rated head:128m Rated flow:0.6+0.3m³/s Frequency:60Hz Outgoing line voltage:440V | CJA475-W-80/2×9 SFW614-12/1180 CJA475-W-80/2×6.5 SFW302-12/990 | 2 | 2012.11 |
10 | UK | Rated head:48.51m Rated flow:0.351m³/s Frequency:50Hz Outgoing line voltage:400V | XJA-W-55B/1x8.5 | 1 | 2012.11 |
11 | UK | Rated head:47.48m Rated flow:0.38m³/s Frequency:50Hz Outgoing line voltage:400V | HL110-WJ-42 | 1 | 2012.11 |
12 | UK | Rated head:25.44m Rated flow:0.332m³/s Frequency:50Hz Outgoing line voltage:400V | HLD54-WJ-50 | 1 | 2012.11 |
13 | UK | Rated head:35.19m Rated flow:0.3m³/s Frequency:50Hz Outgoing line voltage:400V | HLD54-WJ-50 | 1 | 2012.11 |
14 | UK | Rated head:37.82m Rated flow:0.291m³/s Frequency:50Hz Outgoing line voltage:400V | HLD54-WJ-50 | 1 | 2012.11 |
15 | HPP1 Guatemala | Rated head:60m Rated flow:1.24m³/s Frequency:60Hz Outgoing line voltage:440V | HLA575c-WJ-56 SFW600-8/990 | 2 | 2012.8 |
16 | UK | Rated head:58.1m Rated flow:0.169m³/s Frequency:50Hz Outgoing line voltage:400V | XJA-W-40/1×9 SFW100-8/590 | 1 | 2012.04 |
17 | Ecuador | Rated head:38m Rated flow:1.64m³/s Frequency:60Hz Outgoing line voltage:440V | HL220-WJ-50 SFW470-8/990 | 1 | 2012.04 |
18 | Italy | Rated head:43m Rated flow:0.59m³/s Frequency:50Hz Outgoing line voltage:400V | HL110-WJ-42 HLD54-WJ-40 | 2 | 2012.03 |
19 | Pakistan | Type:HL855a Runner diameter:1750mm | 27Mw spare runners | 3 | 2011.11 |
20 | ITALY | Rated head:134m Rated flow:0.25m³/s Frequency:50Hz Outgoing line voltage:400V | CJA475-W-80/2×6.5 SFW250-10/850 | 2 | 2011.06 |
21 | Italy | Rated head:228m Rated flow:0.4m³/s Frequency:50Hz Outgoing line voltage:400V | CJA475-W-85/1×9.5 SFW715-8/1180 | 3 | 2011.05 |
22 | UK | Rated head:61.8m Rated flow:0.221m³/s Frequency:50Hz Outgoing line voltage:400V | XJA-W-42/1×10 SFW100-8/590 | 1 | 2011.03 |
23 | HPP1 Albania | Rated head:379.7m Rated flow:0.685m³/s Frequency:50Hz Outgoing line voltage:10.5KV | CJA475-W-105/2×7.5 SFW2150-8/1730 | 1 | 2010.12 |
24 | HPP2 Albania | Rated head:461.6m Rated flow:0.786m³/s Frequency:50Hz Outgoing line voltage:10.5KV | CJA475-W-115/2×8 SFW3000-8/1730 | 1 | 2010.12 |
25 | Italy | Rated head:29m Rated flow:3.2m³/s Frequency:50Hz Outgoing line voltage:400V | HLD41-WJ-42 HLD74-WJ-60 | 2 | 2010.12 |
26 | Afghanistan | Rated head:36m Rated flow:1.67m³/s Frequency:50Hz Outgoing line voltage:400V | HL295-LJZ-50 SF500--6/850 | 5 | 2010.12 |
27 | Pakistan | Rated head:206m Rated flow:0.89m³/s Frequency:50Hz Outgoing line voltage:6.6kV | CJA475-W-100/2×10 SFW1500-10/1430 | 2 | 2010.08 |
28 | HPP1 Vietnam | Rated head:385m Rated flow:11.24m³/s Frequency:50Hz Outgoing line voltage:13.8kV | HL69-LJ-205 SF37500-10/3600 | 2 | 2010.02 |
29 | Mozambique | Rated head:206.8m Rated flow:0.358m³/s Frequency:50Hz Outgoing line voltage:400V | CJA237-W-80/1×9 SFW570-8/990 | 1 | 2010.04 |
30 | Pakistan | Rated head:47.5m Rated flow:2.62m³/s Frequency:50Hz Outgoing line voltage:6.6kV | HLA696-WJ-68 SFW1000-8/1180 | 3 | 2010.03 |
31 | Italy | Rated head:35m Rated flow:4.25m³/s Frequency:50Hz | HLA696-WJ-82 SFW800-12/1430 HLJF2504-WJ-56 SFW400-8/990 | 3 | 2010.01 |
32 | Italy | Rated head:265m Rated flow:0.734m³/s Frequency:50Hz Outgoing line voltage:6.3kV | CJA475-W-110/2×8.5 SFW1600-10/1730 | 2 | 2009.07 |
33 | Georgia | Rated head:289m Rated flow:1.775m³/s Nozzle No.:2 Bucket No.: 20 Runner Outer Diameter: 1600mm RUNNER DIAMETER: 1300mm | 4000KW Pelton runner change | 3 | 2009.06 |
34 | Vietnam | Rated head:86.2m Rated flow:22.5m³/s Frequency:50Hz Outgoing line voltage:10.5kV | HLA883-LJ-155 SF17000-12/3250 | 2 | 2009.01 |